Description
The H6105-D ( aka CP Control Panel ) is the master of the system that control the slave boards: H6103 and H6104-P
Software
- Real Time O.S.
- Programmable through a simple and powerfull scripting language ( see Hydrover Developement System )
On-board advanced functions
- Automatic input change detection
- Rotary Encoder with push button management
- Gateway interface from USB to CAN
- Active Menu, Bars, Edit field management
Hardware
- Power 12V-24V (Max 36V)
- CPU ARM Cortex M3 100MHz
- Display 128 x 64 monochromatic
- Interfaces USB, RS-232, CAN
- Digital inputs 20 (opto-isolated 0-5V)
- Analog inputs 2 (0-5V)
- On-board CAN termination resistors