Difference between revisions of "System configuration & boards addressing"

From Hydrover
Jump to: navigation, search
(Creata pagina con "= System configuration = = Boards numbering =")
 
Line 1: Line 1:
 +
The configuration of a system require two steps:
 +
 +
* tell to the master how many boards of each type are present
 +
* assing a number to every board
 +
 +
 +
 
= System configuration =
 
= System configuration =
 +
 +
The steps needed to configure the master of the system are:
 +
 +
* connect your PC with an USB to Serial adapter to the [[H6105-D]] serial port
 +
* open PuTTY and create a serial connection with this parameters: <code>115200-N-8-1</code>
 +
* configure the number of [[H6105-E]] boards with '''ce num''' command e.g. <code>ce num 1</code>
 +
* configure the number of [[H6103]] boards with '''io num''' command e.g. <code>io num 1</code>
 +
* configure the number of [[H6104-P]] boards with '''ca num''' command e.g. <code>ca num 1</code>
 +
* save the configuration with the '''save''' command
 +
 +
The number of boards spans from 0 to 20 and are grouped by board type
  
  
  
 
= Boards numbering =
 
= Boards numbering =
 +
 +
The steps needed to assign an address to a board are:
 +
 +
* connect your PC with an USB Type-B cable to the USB port of the slave board
 +
* open PuTTY and create a serial connection with this parameters: <code>115200-N-8-1</code>
 +
* configure the number of the board with '''bnum''' command e.g. <code>bnum 0</code>
 +
 +
The boards address spans from 0 to 19 and are grouped by board type

Revision as of 14:57, 13 June 2017

The configuration of a system require two steps:

  • tell to the master how many boards of each type are present
  • assing a number to every board


System configuration

The steps needed to configure the master of the system are:

  • connect your PC with an USB to Serial adapter to the H6105-D serial port
  • open PuTTY and create a serial connection with this parameters: 115200-N-8-1
  • configure the number of H6105-E boards with ce num command e.g. ce num 1
  • configure the number of H6103 boards with io num command e.g. io num 1
  • configure the number of H6104-P boards with ca num command e.g. ca num 1
  • save the configuration with the save command

The number of boards spans from 0 to 20 and are grouped by board type


Boards numbering

The steps needed to assign an address to a board are:

  • connect your PC with an USB Type-B cable to the USB port of the slave board
  • open PuTTY and create a serial connection with this parameters: 115200-N-8-1
  • configure the number of the board with bnum command e.g. bnum 0

The boards address spans from 0 to 19 and are grouped by board type